LIN - LOX - LAR STORAGE TANKS
MAIN CHARACTERISTICS
• Manufacturing and holding certification in compliance with 2014/68/EU Pressure Equipment Directive (PED) in accordance with EN 13458 - Annex C, AD 2000 Code and ASME (U STAMP), GOST
• Seismic design in line with Euro code 3
• Support / leg design to ensure convenient transportatio
• Valve group design fitted in the lower bow
• Specific design to optimize volume
• High quality paint application by using oven-drying
• Non-destructive inspection methods in accordance with standards (Radiographic test, Penetrant test, Magnetic Particle Test, etc.)
LIN - LOX - LAR STORAGE TANKS
| TYPE | CAPACITY | LENGTH | WIDTH | HEIGHT |
|---|---|---|---|---|
| CCSTR5LLL | 5 m³ | 4780 mm | 2220 mm | 2400 mm |
| CCSTR10LLL | 10 m³ | 7245 mm | 2350 mm | 2310 mm |
| CCSTR15LLL | 15 m³ | 6950 mm | 2750 mm | 2795 mm |
| CCSTR30LLL | 30 m³ | 12360 mm | 2400 mm | 2850 mm |
| CCSTR50LLL | 50 m³ | 13500 mm | 3000 mm | 3050 mm |
DESIGN CONDITIONS
| Design Code | : EN 13458 - ANNEX C, ASME (U STAMP) and GOST |
| Working Pressure | : 5 - 37 bar (MAWP) |
| Design Temperature | : +50 °C / -196 °C |
| Ambient Temperature | : +50 °C / -50 °C |
| Inner Vessel Material | : Stainless Steel in accordance with design codes |
| External Vessel Material | : Carbon, Stainless Steel or Aluminum in accordance with design codes |
| Radioactive Control | : In accordance with design codes |
| Liquid Penetrant Testing | : In accordance with design codes |
| Insulation | : Vacuum and Perlite Insulation |