LIC STORAGE TANKS
MAIN CHARACTERISTICS
• Manufacturing in association with 2014/68/EU Pressure Equipment Directive (PED) , EN 13458, AD 2000 Code, ASME (U STAMP) and GOST
• Seismic design in line with Euro code 3
• Support / leg design to ensure convenient transportation
• Valve group design fitted in the lower bow
• Specific design to optimize volum
• High quality paint application by using oven-drying
• Non-destructive inspection methods in accordance with standards (Radiographic test, Penetrant test, Magnetic Particle Test, etc.)
• LIC Tanks are manufactured according to customer requirements as vacuum insulated or polyurethane insulted
• LIC The inner vessel of LIC Tanks can be manufactured for food or industrial purposes stainless steel or carbon steel according to customer requirements
LIC STORAGE TANKS
TYPE | CAPACITY | LENGTH | WIDTH | HEIGHT |
---|---|---|---|---|
CCSTR3LIC | 3 m³ | 3440 mm | 2335 mm | 2230 mm |
CCSTR5LIC | 5 m³ | 3740 mm | 2335 mm | 2230 mm |
CCSTR10LIC | 10 m³ | 5440 mm | 2400 mm | 2550 mm |
CCSTR15LIC | 15 m³ | 7195 mm | 2750 mm | 2870 mm |
CCSTR22LIC | 22 m³ | 6943 mm | 2805 mm | 3005 mm |
CCSTR30LIC | 30 m³ | 8250 mm | 3050 mm | 3450 mm |
CCSTR50LIC | 50 m³ | 11805 mm | 3210 mm | 3410 mm |
CCSTR400LIC | 400 m³ | 4797 mm | 4550 mm | 30206 mm |
DESIGN CONDITIONS
Design Code | : EN 13458, AD 2000 Code, ASME (U STAMP) and GOST |
Max Allowable Working Pressure | : 22 - 24 bar |
Design Temperature | : -40 °C / +60 °C |
Inner Vessel Material | : Carbon, Stainless Steel in accordance with design codes |
External Vessel Material | : Carbon, Stainless Steel or Aluminum in accordance with design codes |
Radiographic Control | : In accordance with design codes |
Liquid Penetrant Testing | : In accordance with design codes |
Insulation | : Vacuum and Perlite Insulation or PUR Insulation |