AMMONIA STORAGE TANK

MAIN CHARACTERISTICS

• Manufacture in association with EN13445, ASME (U Stamp) and AD 2000 CODE standards, as well as the regulation of the 2014/68 / EU Pressure Equipment Directive (PED)

• Selection of size and anchor according to earthquake and wind load calculations made in accordance with the standards

• Support / leg design to ensure convenient transportation

• High quality paint application by using oven-drying

• Selection of equipment and accessories appropriate to liquefied anhydrous ammonia

• Sheet selection and normalization processes in accordance with liquefied anhydrous ammonia

• Non-destructive inspection methods in accordance with standards (Radiographic test, Penetrant test, Magnetic Particle Test, etc.)

DESIGN CONDITIONS
Design Standarts: EN14025 or ASME SECTION VIII DIV.1
Design Pressure (ADR): 26 bar with thermal insulation 29 bar without thermal insulation
Design Temperature: -40 °C / + 50 °C
Material: Carbon Steel P460NL1 or NL2 P355NL1 or NL2 ASTM A516 Grade 70
Safety System: None / Hermatik