AMMONIA STORAGE TANK
MAIN CHARACTERISTICS
• Manufacture in association with EN13445, ASME (U Stamp) and AD 2000 CODE standards, as well as the regulation of the 2014/68 / EU Pressure Equipment Directive (PED)
• Selection of size and anchor according to earthquake and wind load calculations made in accordance with the standards
• Support / leg design to ensure convenient transportation
• High quality paint application by using oven-drying
• Selection of equipment and accessories appropriate to liquefied anhydrous ammonia
• Sheet selection and normalization processes in accordance with liquefied anhydrous ammonia
• Non-destructive inspection methods in accordance with standards (Radiographic test, Penetrant test, Magnetic Particle Test, etc.)
DESIGN CONDITIONS
Design Standarts | : EN14025 or ASME SECTION VIII DIV.1 |
Design Pressure (ADR) | : 26 bar with thermal insulation 29 bar without thermal insulation |
Design Temperature | : -40 °C / + 50 °C |
Material | : Carbon Steel P460NL1 or NL2 P355NL1 or NL2 ASTM A516 Grade 70 |
Safety System | : None / Hermatik |